ProofKitcheninspection logs

LASAN FOG Control / LA County Public Works Industrial Waste (unincorporated)

Los Angeles, CA grease trap / FOG rules

Not legal advice. Last verified 2026-09-21 · confidence medium. Confirm with the city before you set a contract.

Pumping / cleaning

Minimum interval: No fixed calendar interval in the sources we cited.

Accumulation rule: 25% rule: pump before floating FOG + settled solids reach 25% of liquid depth. High-volume fry programs often need 14–30 days in practice. City of LA FSEs typically need an industrial wastewater permit.

Records: keep required records about 3 years on site.

Hauler: Certified/licensed hauler. Keep manifests.

Permit: City of LA: LASAN industrial wastewater permit. Unincorporated county: IWDP via Public Works.

Enforcement: City sources cite FOG fines that can reach $1,000–$10,000/day. Confirm current schedule with LASAN or County Public Works.

Official sources

Hood cleaning

NFPA 96 frequencies (widely republished by fire departments): solid fuel monthly; high-volume quarterly; moderate semiannual; low-volume annual. Insurers and local fire inspectors can be stricter.

Start a log prefilled for Los Angeles, CA Search inspections